CITY OF PUYALLUP PERMITTING PORTAL

Permit Application Status

PRCTI20240275


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRCTI20240275
Commercial - Tenant Improvement/Remodel
Permit(s) Issued
BCC PUYALLUP LLC
Alteration/Remodel
Installation of foundations and steel supports for exterior chiller piping and electrical conduit, as well as installation of fluid coolers, air cooled chillers, pumps and miscellaneous mechanical equipment - CENTERIS VOLTAGE PARK
02/22/2024
04/23/2024
11/04/2024

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Building Review Approved 04/23/2024 04/16/2024
Engineering Review Approved 04/23/2024 04/10/2024
Planning Review Approved 04/23/2024 04/10/2024
Fire Review Approved 04/23/2024 04/09/2024
Building Review Failed 03/26/2024 03/22/2024
Engineering Review Approved 03/26/2024 03/20/2024
Fire Review Approved 03/26/2024 03/06/2024
Planning Review Approved 03/26/2024 03/05/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 04/17/2024
Building Permit Fee $1,553.75 $1,553.75 Paid 04/17/2024
Building Plan Review Fee $1,009.94 $1,009.94 Paid 02/27/2024
WA State Building Code Council Fee (Commercial) $25.00 $25.00 Paid 04/17/2024
Boilers & Compressors/Heat Pump (over 1,750,000 or over 50 HP) Fee $244.96 $244.96 Paid 04/17/2024
Air Handling Unit (Up to 10,000 cfm) Fee $42.30 $42.30 Paid 04/17/2024
Evaporative Coolers Fee $28.20 $28.20 Paid 04/17/2024
Mechanical Permit Fee $40.00 $40.00 Paid 04/17/2024
Mechanical Plan Review Fee $231.05 $231.05 Paid 04/17/2024
Sump, Sewage, or Ejector Pumps Fee $13.00 $13.00 Paid 04/17/2024
Plumbing Permit Fee $40.00 $40.00 Paid 04/17/2024
Plumbing Plan Review Fee $34.45 $34.45 Paid 04/17/2024
Sewer System Development ChargeFee - Tenant Improvment/Addition $1,730.80 $1,730.80 Paid 04/17/2024
Water System Development ChargeFee - Tenant Improvment/Addition $1,245.65 $1,245.65 Paid 04/17/2024
$5,311.92
Resubmittal Fee $180.00 $180.00 Paid 04/05/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Building Div Inspection Pending
Shannon King ((253) 840-6684)
Comment Engineering Div Inspection Pending
Footing/Setback Inspection Pending
Shannon King ((253) 840-6684)
Slab/Insulation Inspection Pending
Shannon King ((253) 840-6684)
Roof Sheathing Inspection Pending
Shannon King ((253) 840-6684)
Shear Wall Inspection Pending
Shannon King ((253) 840-6684)
Firewall/Firestop Inspection Pending
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection Pending
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection Pending
Shannon King ((253) 840-6684)
Frame Inspection Pending
Shannon King ((253) 840-6684)
Combination Frame And Rough In Inspection Pending
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection Pending
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection Pending
Shannon King ((253) 840-6684)
Exit Lighting Test Inspection Pending
David Drake ((253) 864-4171)
Hydronic Piping Inspection Pending
Shannon King ((253) 840-6684)
Gas Test Inspection Pending
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection Pending
Shannon King ((253) 840-6684)
Refrigeration Line Test Inspection Pending
Shannon King ((253) 840-6684)
Exhaust Hood Inspection Pending
Shannon King ((253) 840-6684)
Light Test For Grease Duct Inspection Pending
Shannon King ((253) 840-6684)
Exhaust/Vent Fans Inspection Pending
Shannon King ((253) 840-6684)
Medical Gas Inspection Pending
Shannon King ((253) 840-6684)
Fire Or Smoke Damper Inspection Pending
David Drake ((253) 864-4171)
Cover Inspection/Thrust Blocks Inspection Pending
Hydrostatic Test 200Lbs 2Hrs Pending
David Drake ((253) 864-4171)
Emergency Radio Test Review Inspection Pending
David Drake ((253) 864-4171)
Engineering Final Inspection Pending
Planning Final Inspection Pending
Fire Final Inspection Pending
David Drake ((253) 864-4171)
Plumbing Final Inspection Pending
Shannon King ((253) 840-6684)
Mechanical Final Inspection Pending
Shannon King ((253) 840-6684)
Building Final Inspection Pending
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection Pending
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection Partial Pass 5/2/2024 5/2/2024 05/02/2024
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection Partial Pass 5/8/2024 5/8/2024 05/08/2024
Kevin Spruell ((253) 841-5590)

Conditions

Condition Status Department Category Expiration Date Due Date
Building Permit Standard Conditions Open Building Division Standard Conditions
: * Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
Fire Review Conditions Open Standard Conditions
: 1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. REAR DOORS OF SUITES OR UNITS SHALL ALSO BE LABELED WITH MINIMUM 4 INCH NUMBERS. 2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 80,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE. 3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE. 4. KNOX BOXES, WHEN REQUIRED, SHALL BE INSTALLED USUALLY TO THE RIGHT OF THE MAIN FRONT DOOR AND NO HIGHER THAN 6 FEET OFF OF THE GROUND. ONLY HINGED KNOX BOXES SHALL BE USED. KNOX BOXES AND KEY SWITCHES CAN BE ORDERED ONLINE AT THE "KNOX COMPANY" 5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION.
SEPA Determination Required Resolved Planning Division Prior to Issuance
: Permit scope subject to SEPA Environmental Review. Permit cannot be issued until associated SEPA Determination appeal period has expired without appeal. SEE SEPA DNS #PLSSP20240018
Contaminated Site Remediation Open Engineering Division Standard Conditions
: The subject property has been classified as a contaminated site by the Tacoma Pierce County Health Department (TPCHD) and must be remediated per Washington Administrative Code Title 173. It is the applicant’s responsibility to coordinate cleanup with TPCHD. Visit https://www.tpchd.org/healthy-places/contaminated-property-cleanup for more information. The applicant shall request a remediation status report from TPCHD by emailing UST@tpchd.org. Provide a copy of the status report to the City.
Miscellaneous Condition Open Engineering Division Standard Conditions
: Prior to starting construction, the contractor shall verify the location and design of the existing storm drain and proposed sanitary sewer line located underneath the proposed project footprint. The general contractor shall be responsible for protecting the utilities as designed under the approved PRCCP20240183 civil plans and maintaining utility separation from all other existing and proposed utilities prior to pouring the concrete pads and installing the footings. Any and all conflicts between the proposed project and and civil design shall be mitigated and corrected at the expense of the permit applicant and property owner. The City shall not be held responsible or liable for any conflicts that arise between the building and civil plans.
Miscellaneous Condition Open Engineering Division Prior to Occupancy
: The applicant shall contact the Puyallup Water Pollution Control Plant by calling 253-841-5511 to apply for a pre-treatment/discharge permit which should include a discharge plan for potential pollutants. Written authorization to proceed with the installation, connection, and use of the proposed chillers and coolers must be obtained from the Puyallup Water Pollution Control Plant prior to resolving this condition. [Yianni Charitou @ 03/07/2024 9:55 AM]
Miscellaneous Condition Open Engineering Division Standard Conditions
: According to UPC Table 702.2(1), the proposed 2" trap serving the new chillers and coolers is equivalent to 4 drainage fixture units. Each sewer fixture unit is currently $432.70 above the first 15 units. $1,730.80 sewer system development charges were assessed for the sewer system that serves the new chillers and coolers. [Yianni Charitou @ 03/20/2024 4:12 PM] According to footnote 2 of UPC Table 610.3, appliances appurtenances, or fixtures not referenced in this table shall be permitted to be sized by reference to fixtures having similar flow rate and frequency of use. For this project, the proposed 1.5" branch supplying the new coolers is sized like a private hose bibb which equals 2.5 water supply fixture units for the first hose bibb and 1 unit for each additional hose bibb. Each water supply fixture unit is currently $355.90 above the first 15 units. Two hose bibbs are assumed to serve the coolers. $1,245.65 water system development charges were assessed for the tank that supplies the new coolers. [Yianni Charitou @ 03/20/2024 4:12 PM]

Related Permit & Planning Applications

Reference Number Status Type
PRFO20231761 Permit(s) Issued Foundation Only
PRFO20240140 Permit(s) Issued Foundation Only
PRCCP20240183 In Plan Check Civil Construction Permit
PRFO20240187 Permit(s) Issued Foundation Only
PRMH20240272 Permit(s) Issued Mechanical - COMMERCIAL ONLY
PRCTI20240333 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240438 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240560 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFO20240573 In Plan Check Foundation Only
PRMH20240593 Permit(s) Issued Mechanical - COMMERCIAL ONLY
PRFS20240598 Permit(s) Issued Fire Sprinklers
PRCNC20240601 In Plan Check Commercial - New Construction
PRFA20240642 Permit(s) Issued Fire Alarms
PRCNC20240647 In Plan Check Commercial - New Construction
PRFN20240667 Returned for Correction Fence
PRCTI20240782 In Plan Check Commercial - Tenant Improvement/Remodel
PLPRE20230121 File Closed Pre-Application
PLSSP20240018 File Closed SEPA Standalone

Documents & Images


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.