Summary

PRMH20240593
Mechanical - COMMERCIAL ONLY
Permit(s) Issued
BCC PUYALLUP LLC
Other
Phase 2 build-out of existing chilled water plant. Scope includes installation of the following fixtures: (1) Water Cooled Chiller and (1) Chilled water pump, (1) Cooling Tower and Condenser Water Pump, (1) Buffer Tank, and (1) Solid Separator. To include piping connections between new equipment to existing system.
04/08/2024
04/25/2024
06/17/2025

Locations

Reviews

Fees

Paid Fees Amount Paid Owing Date Paid
Unclassified Appliance or Equipment Fee $84.60 $84.60 Paid 04/25/2024
Mechanical Permit Fee $40.00 $40.00 Paid 04/25/2024
Mechanical Plan Review Fee $80.99 $80.99 Paid 04/08/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Building Div Inspection Pending
Shannon King ((253) 840-6684)
Gas Test Inspection Pending
Shannon King ((253) 840-6684)
Mechanical Final Inspection Pending
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection Pending
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
12/19/2024
provide test on all piping not tested at time of inspection as discussed with Todd .

Mechanical Rough In Inspection Not Ready 11/25/2024 11/25/2024 11/25/2024
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
11/25/2024
provide test on all piping not tested at time of inspection as discussed with Todd .

Mechanical Rough In Inspection Partial Pass 12/19/2024 12/19/2024 12/19/2024
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
12/19/2024
provide test on all piping not tested at time of inspection as discussed with Todd .

Conditions

Condition Status Department Category Expiration Date Due Date
Building Permit Standard Conditions Open Building Division Standard Conditions
: * Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp

Related Permit & Planning Applications

Reference Number Status Type
PRFO20231761 Closed Foundation Only
PRFO20240140 Permit(s) Issued Foundation Only
PRCCP20240183 Permit(s) Issued Civil Construction Permit
PRFO20240187 Permit(s) Issued Foundation Only
PRMH20240272 Permit(s) Issued Mechanical - COMMERCIAL ONLY
PRCTI20240275 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240333 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240438 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240560 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFO20240573 Permit(s) Issued Foundation Only
PRFS20240598 Closed Fire Sprinklers
PRCNC20240601 Permit(s) Issued Commercial - New Construction
PRFA20240642 Closed Fire Alarms
PRCNC20240647 Permit(s) Issued Commercial - New Construction
PRFN20240667 Permit(s) Issued Fence
PRCTI20240782 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240784 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20240822 Closed Fire Alarms
PRMH20240831 Permit(s) Issued Mechanical - COMMERCIAL ONLY
PRCTI20240892 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20241312 Closed Fire Alarms
PRCTI20241387 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20241456 Closed Fire Alarms
PRFA20241475 Permit(s) Issued Fire Alarms
PRFS20241490 Closed Fire Sprinklers
PRCNC20241741 Ready for Issuance Commercial - New Construction
PRMH20241875 Permit(s) Issued Mechanical - COMMERCIAL ONLY
PRRWF20241913 Returned for Correction Retaining Wall
PRCTI20242004 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20250032 Returned for Correction Commercial - Tenant Improvement/Remodel
PRFA20250095 In Plan Check Fire Alarms
PLPRE20230121 File Closed Pre-Application
PLSSP20240018 File Closed SEPA Standalone

Documents & Images

Date Uploaded File Type Name
04/08/2024 Receipt Receipt for transaction:2024-000694
04/24/2024 Other Buffer Tank BT-1 (Stamped)
04/24/2024 Other CUT SHEET - Chilled Water Condenser Pump CWP-3 (Stamped)
04/24/2024 Other CUT SHEET Chilled Water Primary Pump CHP-3 (Stamped)
04/24/2024 Other CUT SHEET Condensate Pumps CP1 and CP2 (Stamped)
04/24/2024 Other CUT SHEET Solid Separator SS-1 (Stamped)
04/24/2024 Plans FLOOR PLAN - Expansion Mech Permit Set (Stamped)
04/24/2024 Other Marley Cooling Tower CT-3 (Stamped)
04/24/2024 Plans MECHANICAL PLANS (Stamped)
04/24/2024 Form MECHANICAL REQUIREMENTS LIST (Stamped)
04/24/2024 Other Polaris Plate & Frame Heat Exchanger HX-2 (Stamped)
04/24/2024 Other STRUCTURAL DESIGN CRITERIA (Stamped)
04/24/2024 Plans STRUCTURAL PLAN - Centeris Data Center - Scale Matrix TI S (Stamped)
04/24/2024 Form WSEC MECHANICAL COMPLIANCE SUMMARY (Stamped)
04/24/2024 Other York Chiller Chiller CH-3 (Stamped)
04/25/2024 Letter Permit - Detailed
04/25/2024 Receipt Receipt for transaction:2024-000852
09/09/2024 Letter Permit Expiration Notice
11/25/2024 Report Inspection Report (Mechanical Rough In Inspection)


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.