Development Permit Application Status

PRFA20260831


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20260831
Fire Alarms
In Plan Check
BENAROYA CAPITAL COMPANY LLC
Alteration/Remodel
Level 2 T.I. to move (5) existing ceiling mount horn strobes to new wall mount location. Level 3 T.I. add (1) new monitor module to monitor AHU built-in smoke detector, add (1) relay module to shutdown AHU unit when detector is in alarm. All existing fire alarm panel, field devices and sequence of operations to remain the same. - CENTERIS, ROW-D
06/10/2026

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Pending 07/06/2026

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $132.25 $132.25 Paid 06/10/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

There are no inspections for this development permit application, or you are not authorized to view them.

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- A REMOTE ANNUCIATOR LOCATED ON THE EXTERIOR OF THE MAIN ENTRANCE IN A WEATHER PROOF HOUSING REQUIRED. 5- EXTERIOR FIRE BELL REQUIRED OUTSIDE FIRE SPRINKLER ROOM. 6- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 7- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 8- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 9- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 10- FIRE SPRINKLER TAMPER VALVES AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. FIRE SPRINKLER CONTRACTOR TO BE ONSITE. 11- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE.
Possible Contamination Advisory Notice Open Standard Conditions
Engineering Division
Please be advised, the subject property may be flagged as a contaminated site by the Washington State Department of Ecology. Further action may or may not be required. As a courtesy, the City of Puyallup is notifying permit applicants of the possible contamination prior to construction. The City is not placing a hold on the development permit or notice against the property title for the possible contamination, but rather informing the permit holder and contractor prior to any ground disturbing activities. Please direct any inquiries or questions regarding the status of the contamination to the Tacoma Pierce County Health Department (TPCHD) by emailing UST@tpchd.org. For more information on contaminated sites, please visit https://www.tpchd.org/healthy-places/contaminated-property-cleanup. No further action is required with the City of Puyallup as it relates to this development permit.

Related Permit & Planning Applications

Reference Number Status Type
PRFO20231761 Closed Foundation Only
PRFO20240140 Closed Foundation Only
PRCCP20240183 Permit(s) Issued Civil Construction Permit
PRFO20240187 Permit(s) Issued Foundation Only
PRMH20240272 Closed Mechanical - COMMERCIAL ONLY
PRCTI20240275 Closed Commercial - Tenant Improvement/Remodel
PRCTI20240333 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240438 Closed Commercial - Tenant Improvement/Remodel
PRCTI20240560 Closed Commercial - Tenant Improvement/Remodel
PRFO20240573 Closed Foundation Only
PRMH20240593 Closed Mechanical - COMMERCIAL ONLY
PRFS20240598 Closed Fire Sprinklers
PRCNC20240601 Closed Commercial - New Construction
PRFA20240642 Closed Fire Alarms
PRCNC20240647 Closed Commercial - New Construction
PRFN20240667 Closed Fence
PRCTI20240782 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20240784 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20240822 Closed Fire Alarms
PRMH20240831 Closed Mechanical - COMMERCIAL ONLY
PRCTI20240892 Closed Commercial - Tenant Improvement/Remodel
PRFA20241312 Closed Fire Alarms
PRCTI20241387 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20241456 Closed Fire Alarms
PRFA20241475 Permit(s) Issued Fire Alarms
PRFS20241490 Closed Fire Sprinklers
PRCNC20241741 Permit(s) Issued Commercial - New Construction
PRMH20241875 Closed Mechanical - COMMERCIAL ONLY
PRRWF20241913 Closed Retaining Wall
PRCTI20242004 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20250032 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20250095 Permit(s) Issued Fire Alarms
PRFS20250257 Closed Fire Sprinklers
PRFA20250292 Closed Fire Alarms
PRCTI20250361 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFA20250454 Closed Fire Alarms
PRFA20250542 Closed Fire Alarms
PRFA20250621 Closed Fire Alarms
PRFS20250986 Permit(s) Issued Fire Sprinklers
PRFS20251390 Closed Fire Sprinklers
PRFA20251430 Closed Fire Alarms
PRCTI20260575 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PLPRE20230121 File Closed Pre-Application
PLSSP20240018 File Closed SEPA Standalone
PLBDJ20260066 Complete Application Boundary Line Adjustment

Documents & Images

Date Uploaded File Type Name
06/10/2026 Receipt Receipt for transaction:2026-001065


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.