Summary

PRFA20250684
Fire Alarms
Permit(s) Issued
EAST TOWN CROSSING LLC
New
ISSUED AS BUILDING H Install complete Fire Alarm system that will monitor the sprinkler system. will report to 3rd party monitoring. - EAST TOWN CROSSING - REASSIGNED AS 3002 E PIONEER - BLDG J
05/21/2025
06/11/2025
12/08/2025

Locations

Address
1001 SHAW RD, PUYALLUP, WA 98372

Property
0420264021

3002 E PIONEER WAY, BUILDING J, PUYALLUP WA

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 06/23/2025 06/09/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $517.50 $517.50 Paid 05/21/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • A remote annunciator located at the main entrance is required. If there is an existing annunciator on the exterior of the building it will need to be moved inside the main entrance. Please contact fire inspector for further information. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72, 2016 • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCCP20230970 Permit(s) Issued Civil Construction Permit
PRGR20230972 Permit(s) Issued Clear, Fill, & Grade Permit
PRHM20231330 Closed Hydraulic Modeling
PRCNC20231714 Canceled Commercial - New Construction
PRMU20240139 Permit(s) Issued Residential - New Multi-Unit
PRHM20240180 Closed Hydraulic Modeling
PRMU20240400 Permit(s) Issued Residential - New Multi-Unit
PRMU20240401 Permit(s) Issued Residential - New Multi-Unit
PRMU20240402 Permit(s) Issued Residential - New Multi-Unit
PRMU20240404 Permit(s) Issued Residential - New Multi-Unit
PRMU20240405 Permit(s) Issued Residential - New Multi-Unit
PRMU20240406 Permit(s) Issued Residential - New Multi-Unit
PRMU20240407 Returned for Correction Residential - New Multi-Unit
PRGR20240491 Permit(s) Issued Clear, Fill, & Grade Permit
PRCCP20240569 Permit(s) Issued Civil Construction Permit
PRCCP20240808 Permit(s) Issued Civil Construction Permit
PRFS20241973 Permit(s) Issued Fire Sprinklers
PRFS20250031 Permit(s) Issued Fire Sprinklers
PRFS20250098 Permit(s) Issued Fire Sprinklers
PRFS20250099 Permit(s) Issued Fire Sprinklers
PRFS20250371 Permit(s) Issued Fire Sprinklers
PRCTI20250375 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRRWF20250442 Permit(s) Issued Retaining Wall
PRFS20250456 Permit(s) Issued Fire Sprinklers
PRFS20250522 Permit(s) Issued Fire Sprinklers
PRCNC20250528 In Plan Check Commercial - New Construction
PRFA20250599 Permit(s) Issued Fire Alarms
PRCNC20250692 In Plan Check Commercial - New Construction
PRCP20250695 In Plan Check Carport
P-20-0027 Expired SEPA Standalone
P-20-0042 Expired MISCELLANEOUS PLANNING PERMIT
P-20-0028 Expired MISCELLANEOUS PLANNING PERMIT
L-20-0002 Expired Comprehensive Plan Amendment
P-20-0077 Expired Pre-Application
P-21-0025 Expired Short Plat
P-21-0034 File Closed Preliminary Site Plan
P-19-0010 Canceled Development Agreement
P-20-0031 Expired Pre-Application
PLBDJ20240103 File Closed Boundary Line Adjustment

Documents & Images

Date Uploaded File Type Name
05/21/2025 Receipt Receipt for transaction:2025-000982
05/22/2025 Letter Incomplete Application Notice
06/11/2025 Plans FIRE ALARM PLANS (Stamped)
06/11/2025 Plans FIRE ALARM SYSTEM CALCULATIONS (Stamped)
06/11/2025 Plans FIRE ALARM DEVICE CUT SHEET (Stamped)
06/11/2025 Permit Permit - Detailed