| Review Type |
Outcome |
Est. Completion Date |
Completed |
|
Planning Review
|
Approved
|
11/20/2025
|
11/06/2025
|
|
|
|
|
Building Review
|
Approved
|
11/20/2025
|
11/06/2025
|
|
|
|
|
|
See Document Markup
The vertical distance between the pool coping edge, deck, or step surface and the uppermost recessed tread shall be not greater than 12 inches. This detail shows the coping curving upwards; therefore the 12" maximum dimension to the first step should be from the highest point of the coping edge.
|
|
|
See Document Markup
Main Drains, or suction outlets, are not allowed in wading pools per section 405.6 of the 2021 Washington State Swimming Pool and Spa Code.
"Wading pools shall not have suction outlets. Skimmers or overflow gutters shall be installed and shall accommodate 100 percent of the circulation system flow rate."
|
|
|
See Document Markup
Please provide a section drawing of the wading pool to ensure code compliance. Include the step's rise and run, floor slope (if applicable), distance from the deck to the waterline, and any other relevant information.
|
|
|
See Document Markup
Table 315.3 in the 2021 Washington State Swimming Pool and Spa Code requires one skimmer per 500sq.ft. of pool area. For a 1,125sq.ft. pool, three skimmers will be required; however, the plans only show two.
Note: Per section 315.2.1, "Circulation Systems":
Public pool circulation systems shall be designed to process not less than 100 percent of the turnover rate through skimmers.
|
|
|
See Document Markup
Please see the comment on sheet SP1 regarding main drains at the wading pool.
|
|
Engineering Review
|
Approved
|
11/20/2025
|
11/06/2025
|
|
|
|
|
|
See Document Markup
Draining of the pool shall comply with applicable county health department requirements. Moreover, pool water shall be dechlorinated and have a neutral PH prior to entering a storm sewer system. Indicate how the pool water will be dechlorinated and neutralized prior to discharging to the sanitary sewer system.
|
|
|
See Document Markup
Correlate supply piping to existing utilities installed under East Town Crossing Phase 2 civil plans. Consider adding the water meter to the diagram and indicate whether the proposed RPBA has been installed by others or going to be installed with this proposal.
|
|
Building Review
|
Failed
|
10/08/2025
|
09/29/2025
|
|
|
|
|
|
See Document Markup
Please provide footing details and specifications.
|
|
|
See Document Markup
The vertical distance between the pool coping edge, deck, or step surface and the uppermost recessed tread shall be not greater than 12 inches. This detail shows the coping curving upwards; therefore the 12" maximum dimension to the first step should be from the highest point of the coping edge.
|
|
|
See Document Markup
Please clarify the design of the gate. There appears to be a post on either side of the gate door with a cross bar connecting the top of the posts. The top of the gate crossbar is noted to be 6ft from the walking surface, which falls below the required 80" clear opening height.
|
|
|
See Document Markup
Main Drains, or suction outlets, are not allowed in wading pools per section 405.6 of the 2021 Washington State Swimming Pool and Spa Code.
"Wading pools shall not have suction outlets. Skimmers or overflow gutters shall be installed and shall accommodate 100 percent of the circulation system flow rate."
|
|
|
See Document Markup
Please provide a section drawing of the wading pool to ensure code compliance. Include the step's rise and run, floor slope (if applicable), distance from the deck to the waterline, and any other relevant information.
|
|
|
See Document Markup
Table 315.3 in the 2021 Washington State Swimming Pool and Spa Code requires one skimmer per 500sq.ft. of pool area. For a 1,125sq.ft. pool, three skimmers will be required; however, the plans only show two.
Note: Per section 315.2.1, "Circulation Systems":
Public pool circulation systems shall be designed to process not less than 100 percent of the turnover rate through skimmers.
|
|
|
See Document Markup
Please see the comment on sheet SP1 regarding main drains at the wading pool.
|
|
Engineering Review
|
Failed
|
10/08/2025
|
09/25/2025
|
|
|
|
|
|
See Document Markup
Overlay the pool piping plan from the construction plan set on the site plan. Address any utility crossing or separation conflicts.
|
|
|
See Document Markup
An approved reduced pressure backflow assembly (RPBA) device is required to be installed on the domestic water service to the clubhouse per City Standard Detail 03.04.02 since the potable water service will have a direct connection to the pool. Depict and label the premise isolation RPBA on the site plan.
|
|
|
See Document Markup
Draining of the pool shall comply with applicable county health department requirements. Moreover, pool water shall be dechlorinated and have a neutral PH prior to entering a storm sewer system. Indicate how the pool water will be dechlorinated and neutralized prior to discharging to the sanitary sewer system.
|
|
|
See Document Markup
Correlate supply piping to existing utilities installed under East Town Crossing Phase 2 civil plans. Consider adding the water meter to the diagram and indicate whether the proposed RPBA has been installed by others or going to be installed with this proposal.
|
|
Planning Review
|
Approved
|
10/08/2025
|