CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20251007


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20251007
Fire Alarms
In Plan Check
EAST TOWN CROSSING LLC
New
SUBMITTED AS BLDG E (140) ALARMS ~ ISSUED AS 3002 E PIONEER, BLDG B
07/23/2025

Locations

Property
0420264021

3002 E PIONEER, BLDG B, PUYALLUP, 98372

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Pending 08/18/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $517.50 $517.50 Paid 07/23/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

There are no inspections for this development permit application, or you are not authorized to view them.

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- A REMOTE ANNUCIATOR LOCATED ON THE EXTERIOR OF THE MAIN ENTRANCE IN A WEATHER PROOF HOUSING REQUIRED. 5- EXTERIOR FIRE BELL REQUIRED OUTSIDE FIRE SPRINKLER ROOM. 6- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 7- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 8- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 9- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 10- FIRE SPRINKLER TAMPER VALVES AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. FIRE SPRINKLER CONTRACTOR TO BE ONSITE. 11- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE.

Related Permit & Planning Applications

Reference Number Status Type
PRCCP20230970 Permit(s) Issued Civil Construction Permit
PRGR20230972 Permit(s) Issued Clear, Fill, & Grade Permit
PRHM20231330 Closed Hydraulic Modeling
PRCNC20231714 Canceled Commercial - New Construction
PRMU20240139 Permit(s) Issued Residential - New Multi-Unit
PRHM20240180 Closed Hydraulic Modeling
PRMU20240400 Permit(s) Issued Residential - New Multi-Unit
PRMU20240401 Permit(s) Issued Residential - New Multi-Unit
PRMU20240402 Permit(s) Issued Residential - New Multi-Unit
PRMU20240404 Permit(s) Issued Residential - New Multi-Unit
PRMU20240405 Permit(s) Issued Residential - New Multi-Unit
PRMU20240406 Permit(s) Issued Residential - New Multi-Unit
PRMU20240407 Returned for Correction Residential - New Multi-Unit
PRGR20240491 Permit(s) Issued Clear, Fill, & Grade Permit
PRCCP20240569 Permit(s) Issued Civil Construction Permit
PRCCP20240808 Permit(s) Issued Civil Construction Permit
PRFS20241973 Closed Fire Sprinklers
PRFS20250031 Permit(s) Issued Fire Sprinklers
PRFS20250098 Permit(s) Issued Fire Sprinklers
PRFS20250099 Closed Fire Sprinklers
PRFS20250371 Permit(s) Issued Fire Sprinklers
PRCTI20250375 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRRWF20250442 Closed Retaining Wall
PRFS20250456 Permit(s) Issued Fire Sprinklers
PRFS20250522 Permit(s) Issued Fire Sprinklers
PRCNC20250528 Permit(s) Issued Commercial - New Construction
PRFA20250599 Closed Fire Alarms
PRFA20250684 Closed Fire Alarms
PRCNC20250692 Permit(s) Issued Commercial - New Construction
PRCP20250695 Permit(s) Issued Carport
PRFA20250795 Permit(s) Issued Fire Alarms
PRFA20250797 Permit(s) Issued Fire Alarms
PRSG20250876 Returned for Correction Sign/Awning
PRSG20250877 Returned for Correction Sign/Awning
PRSG20250878 Returned for Correction Sign/Awning
PRCP20250899 Permit(s) Issued Carport
PRCP20250900 Permit(s) Issued Carport
PRCP20250901 Permit(s) Issued Carport
PRCP20250902 Permit(s) Issued Carport
PRCP20250903 Permit(s) Issued Carport
PRCP20250904 Permit(s) Issued Carport
PRCP20250905 Returned for Correction Carport
PRCP20250906 Returned for Correction Carport
PRCP20250907 Returned for Correction Carport
PRCP20250908 Returned for Correction Carport
PRCP20250909 Returned for Correction Carport
PRCP20250910 Returned for Correction Carport
PRCP20250911 Returned for Correction Carport
PRCP20250912 Returned for Correction Carport
PRCP20250913 Returned for Correction Carport
PRFA20250945 Permit(s) Issued Fire Alarms
PRFA20250946 Permit(s) Issued Fire Alarms
PRCP20250957 Returned for Correction Carport
PRFA20251024 In Plan Check Fire Alarms
PRFA20251055 In Plan Check Fire Alarms
P-20-0027 Expired SEPA Standalone
P-20-0042 Expired MISCELLANEOUS PLANNING PERMIT
P-20-0028 Expired MISCELLANEOUS PLANNING PERMIT
L-20-0002 Expired Comprehensive Plan Amendment
P-20-0077 Expired Pre-Application
P-21-0025 Expired Short Plat
P-21-0034 File Closed Preliminary Site Plan
P-19-0010 Canceled Development Agreement
P-20-0031 Expired Pre-Application
PLBDJ20240103 File Closed Boundary Line Adjustment

Documents & Images

No documents are currently available for viewing.


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.